ECO Ex Pulse Amplifiers Single / double tap with different output functions
Our ECO Ex pulse amplifiers can be equipped with all KEM flow meters. The amplifier system includes a single tap with temperature range up to +150 °C and double tap for higher resolutions or bi-directional flow measurement with standardized push-pull output stage.
Features & Benefits Compact design for flow meters Medium temperatures up to +150°C [+302°F] Scalable analog and digital outputs Flow direction detection Customer configurable Linearisation with up to 20 points possible Integrated Medium Temp. Measurement Functions & Specifications Power Supply (Vcc)12 ... 28 VDC, regulated Current Consumption< 25 mA Frequency Range1 ... 5.000 Hz; suitable for all KEM volumetric counters Ambient Temperature-40 °C ... +60 °C [-40 °F ... +140 °F] Medium TemperatureFlush- Mount (1-or 2Channel) -40 °C ... +80 °C [-40 °F ... +176 °F]
Screwin M14x1.5 (1Channel) -40 °C ... +120 °C [-40 °F ... +248 °F] -40 °C ... +150 °C [-40 °F ... +302 °F]
Output Signal1:1- Frequency or Direction signal & doubled Frequency scaled output values LED indicator for status display Protection ClassAluminium IP65 Stailness Steel IP68 with closed electical connection CertificatesCSACa 23ATEX1003X Issue 0 CSAE 23UKEX1069X Iss 0 IECEx_CSA_23.0019_000