1. technical performance

● to subject: liquid, gas or vapour

● range ability:



LU-CGPS-1200
0-0.25-1.5KPa
LU-CGPS-1300
0-1.2-7.2Kpa
LU-CGPS-1400
0-6-36Kpa
LU-CGPS-1500
0-30-180Kpa
LU-CGPS-1600
0-160-1000Kpa
LU-CGPS-1700
0-400-2500KPa
LU-CGPS-1800
0-1600-10000Kpa
LU-CGPS-1900
0-4000-25000Kpa
LU-CGPS-1000
0-7000-40000Kpa


● output: 4-20mA DC

● power: 24VDC, it may be 12VDC if non-load, max. is 45VDC

● load characteristic:

● positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.

Max. positive transfer: 500% of the min. span.

Max. negative transfer: 600% of the min. span.

● Temperature:

temperature of operating for amplifier: -25℃ ~ +90℃

temperature of operating for sensor: -40℃ ~ +104℃

● Relative humidity: 0~100%

● Sensor capacity changes: <0.16cm3

● Indicate meter (field): scale gauge length: 30mm,

grade: 2.5

● Isolating explosion: ds Ⅱ BT5, Intrinsically-safety: ia Ⅱ CT5

● Span & Zero: external continually adjusted

● Over-pressure: 0 (absolute pressure) –14Mpa, when range < 6Mpa;

0 (absolute pressure) –32Mpa, when range < 20Mpa;

0 (absolute pressure) –52Mpa, when range < 42Mpa;

no damage for transmitter but may cause zero shift, suggest not to operate over-pressure, the max. pressure is 60Mpa for flange template.

● Damp: continually adjusted when time constant is between 0.2~1.67 seconds.

● Settling time: 2s,



2. performance index (note: test under the condition of none shift, max. range status of sensor, 316L stainless isolating diaphragm and other standard condition)

● Accuracy: ±0.25% of the span, including the synthesize errors of linear, change-difference and repeat.

● Stability: ±0.25% of max. range (12 months)



● Temperature affect:

zero error:±0.5% / 55℃, zero & range errors:±1.0% / 55℃, when max. range;

zero error:±3.0% / 55℃, zero & range errors:±3.5% / 55℃, when min. range;

note: for type LU-CGPS-1200 (1300), temperature affect is double times of above

● Over-pressure affect: ±0.25% of max. range (according to permitted over-loads for different ranges)

● vibration affect: ±0.05% / g of the max. range, when 200Hz, any axis up.

● Power affect: <0.005%/V of output range

● Load affect: none affect when voltage >12VDC input to the transmitter.

● Mounting position affect: may cause zero error max. 0.24Kpa, but can be calibrated, none affect for range



3. structure index:

● Structure material: diaphragm: 316 stainless steel, hastelloy C, Monel alloy, Tantalum;

O ring: Fluorin rubber;

Flange & bolt: 316 stainless steel;

Fill oil: silicon oil;

Electric shell: low-Cu & aluminum alloy

Plating of electric shell: toast lacquer of amido, formyl, ethene & colophony;

● pressure-lead connector:

flange NPT 1/4 (taper pipe screw thread), (this is the transmitter flange connection);

connection head screw thread NPT 1/2 (taper pipe screw thread), (selected);

integrated needle valve of welded conduit connector (selected)

● electric parts connector:

down-lead conduit NPT 1/2 line-through hole;

electric cable connector (selected)

explosion-proof connector (selected)

● net weight: 2.4kg (exclude the selected parts)