Back to Top

Hi, Guest!

  LOKASI :  Kota Bogor

Bergabung Selama : 17 Tahun

BAGIKAN :   

Bagikan :
Kontak Kami  
Instrumentation & Valves

LU-CHP electric capacity high static-pressure differential-pressure tr

Update Terakhir
:
06 / 01 / 2023
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
5 kali

Harga

CALL
Bagikan
:
*Instrumentation, Control System, Automation, Cooler & Heat Exchanger, Electrical, Mechanical, Analyzers, Fabricator & Engineering Service & Training*

Detail LU-CHP Electric Capacity High Static-pressure Differential-pressure Tr

LU-CHP electric capacity high static-pressure differential-pressure transmitter

1.technical performance

·to subject: liquid, gas or vapour

·range ability:

LU-CHPS-7400
0-6-36kpa
LU-CHPS-8400
LU-CHPS-9400
LU-CHPS-7500
0-30-180kpa
LU-CHPS-8500
LU-CHPS-9500
·output: 4-20mA DC

·power: 24VDC, it may be 12VDC if non-load, max. is 45VDC

·positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.

Max. positive transfer: 500% of the min. span.

Max. negative transfer: 600% of the min. span.

·Temperature:

temperature of operating for amplifier: -25℃ ~ +90℃

temperature of operating for sensor: -40℃ ~ +104℃

·Relative humidity: 0~100%

·Sensor capacity changes: <0.16cm3

·Indicate meter (field): scale gauge length: 30mm,

grade: 2.5

·Isolating explosion: ds Ⅱ BT5, Intrinsically-safety: ia Ⅱ CT5

·Span & Zero: external continually adjusted

·Static-pressure and Over-pressure limit:

Max. operating pressure: 32Mpa

Max. safe pressure: 32Mpa

Single-side Max. pressure: 32Mpa

Flange bear pressure: 60Mpa

·Static-pressure affect:

zero error: <±2% of max. range, when operating pressure is 32Mpa

range error: is a system error, can be calibrated.

·Damp: continually adjusted when time constant is between 0.2~1.67 seconds.

·Settling time: 2s,



2. performance index (note: test under the condition of none shift, max. range status of sensor, 316L stainless isolating diaphragm and other standard condition)

·Accuracy: ±0.25% of the span, including the synthesize errors of linear, change-difference and repeat.

·Stability: ±0.25% of max. range (12 months)

·Temperature affect:

zero error:±0.5% / 55℃, zero & range errors:±1.0% / 55℃, when max. range;

zero error:±3.0% / 55℃, zero & range errors:±3.5% / 55℃, when min. range;

·Over-pressure affect: ±1%~±5% of max. range (according to permitted over-loads for different ranges)

·vibration affect: ±0.05% / g of the max. range, when 200Hz, any axis up.

·Power affect: <0.005%/V of output range

·Load affect: none affect when voltage >12VDC input to the transmitter.

·Mounting position affect: may cause zero error max. 0.24Kpa, but can be calibrated, none affect for range



3. structure index:

·Structure material: diaphragm: 316 stainless steel, hastelloy C, Monel alloy, Tantalum;

O ring: Fluorin rubber;

Flange & bolt: 316 stainless steel;

Fill oil: silicon oil;

Electric shell: low-Cu & aluminum alloy

Plating of electric shell: toast lacquer of amido, formyl, ethene & colophony;

·pressure-lead connector:

flange NPT 1/4 (taper pipe screw thread), (this is the transmitter flange connection);

connection head screw thread NPT 1/2 (taper pipe screw thread), (selected);

·electric parts connector:

down-lead conduit NPT 1/2 line-through hole;

·net weight: 2.4kg (exclude the selected parts)

Pressure Transmitter
Tampilkan Lebih Banyak