Detail Remote-sealed Gauge Pressure Transmitters Model JTH9_ _ _
Remote-sealed Gauge Pressure Transmitters Model JTH9_ _ _
Model No.
JTH920S, JTH920W, JTH940S, JTH940W, JTH960S, JTH960W, JTH980S, JTH980W.
Remote-sealed Gauge Pressure Transmitters (Model JTH9_ _ _) are used to measure pressure (pressure, fluid level, etc.) of very hot as well as highly corrosive and condensable fluids. We offer an extensive lineup including small bore flange models starting at 40A and models for high temperature (including high temperature high vacuum) applications.
Model
JTH920_
JTH940_
JTH960_
JTH980_
Measuring span
2.5 to 100 kPa
35 to 3500 kPa
0.7 to 10 Mpa
0.7 to 42 MPa
Setting range
-100 to 100 kPa
-100 to 3500 kPa
-0.1 to 10 Mpa
-0.1 to 42 MPa
Reference accuracy(Varies by material and measuring span)
±0.15%
±0.15%
±0.15%
±0.15%
Fill fluid
Silicone oil(for general purpose and high temperature models)
Silicone oil (for general purpose, high temperature,high temperature vacuum, and high temperature high vacuum models)
Silicone oil(for general purpose models)
Fluorine oil(oxygen and chlorine models)
Fluorine oil (oxygen and chlorine models)
Fluorine oil(oxygen models)
Waterproof and dust-proof construction
IEC IP66/IP67
Explosion-proof construction
TIIS explosion proof (Exd IICT4)
Range of operating temperatures for liquid part(Varies with pressure)
Silicone oil: -40 to 280 °C (varies with fill fluid)
Silicone oil:-40 to 180 °C
Fluorine oil: -10 to 120 °C
Fluorine oil: -10 to 120 °C
Range of operating pressures for liquid part(Varies with temperature)
Silicone oil General purpose and high temperature models: from 2 kPa abs 2 kPa abs~
Silicone oil General purpose and high temperature models: from 2 kPa abs
High temperature vacuum and high temperature high vacuum models: 0.13 kPa abs
Silicone oil: from 2 kPa abs
Fluorine oil: from 53 kPa abs
Fluorine oil: from 53 kPa abs
Fluorine oil: from 54 kPa abs
Wetted material
SUS316 (diaphragm SUS316L), Hastelloy C, Tantalum
SUS316 (diaphragm SUS316L)
Power
17.9 to 45 V DC
Output signal
4 to 20 mA DC (SFN communication), 4 to 20 mA DC (HART® communication)
Process connections
Flush type: 80 mm
Flush type: 80 mm, 50 mm, 40 mm
Button diaphragm type
Protruding type: 100 mm
Protruding type: 100 mm, 80 mm, 50 mm
2B wafer type
2B wafer type
2B wafer type
Tampilkan Lebih Banyak