Detail Vacuum Deposition Model SD/LD-450

Oxygen AnalyzersFor Vacuum Deposition, Sealed Furnaces, and Gloveboxes

SD/LD-450
Model: SD/LD-450


Flexible setup layout. The oxygen sensor and low-profile converter are separated, greatly relaxing limitations on where the device can be installed.
Space saving. The newly developed low-profile wall mounted converter eliminates concerns about the device’s depth.
Ultra-high-speed response. The separated sensor provides the fastest response speed.
Highly durable sensor. A special coating is used for even greater durability.
Compliant standards. Compliant with CE marking, EN61010-1, EN61326-1, and RoHS. Sputtering systems, equipment gas purity management, factory pipe Ar weld management, experimental equipment, and testing equipment
Sensors are compatible with NW flanges (16, 25, 40) for vacuum and screw-in units (3/8R).Select the appropriate type for use condition.
Installation example (SD sensor and LD-450 converter work in pairs.)


SD/LD-450 specifications
Measurement principle
Zirconia concentration cell type
Type
Separate-type (converter: wall-mounted; sensor: direct insertion type)
Display system
4-digit digital display (concentration display)
Measurement range
0-1 / 10 / 100 / 1000ppm / 1 / 10 / 100vol%O2 10-20~10-0atm
Automatic/fixed range
Repeatability
Within ±0.5% of full scale; range of 0-1% or more
Within ±1% of full scale or ±1ppm, whichever is larger; range of less than 0-1%
Concentrations in the 0-1 ppm, atm range are out of warranty.
Sample gas requirements

Pressure
10-3 to 200 KPa (absolute pressure)
Flow rate
0.5 to 5,000 mL/min or 0 mL/min (measurement in state of natural dispersion)
Humidity
Dew point below ambient temperature
Temperature
0 to 100°C
Others
Must not contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable substances (including gas), oil or moisture
Reference gas
Atmosphere
Recorder output
Oxygen concentration output
4-20m (choice between this and transmission output)
Insulated; load resistance of 550 Ω or less
Recorder output range taken as full scale, and oxygen concentration given in linear output

Output range
0-100%, 0-1000ppm, 0-100ppm, 0-10ppm Automatic/fixed range
Transmission output
RS-232C(choice between this and analog output)
Alarm output
FAIL (device error)
1 point
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less
Contact point closes when device error occurs (contact point operation is adjustable)

ALM (concentration alarm)
4 points (HH/H/L/LL)
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less
Contact point closes when alarm occurs (contact point operation is adjustable)
RDY (warmup signal)
1 point
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or lessMinimum open/close capacity of the non-voltage contact point is 12 V or higher; does not respond to extremely small loads
MRK (range marker) output
2 points
Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.3 A or less
Warmup time
6 minutes or less
Dimensions
Converter
185 mm (W) ×155 mm (H)×40 mm (D)  (excluding projecting parts)
Sensor unit
SD3/8R
Overall length 100mm(sensor ⌀ 11×37,body ⌀ 40×48.5)

SD16NW
Overall length 100mm(sensor ⌀ 11×39,body ⌀ 40×51)
SD25NW
Overall length 100mm(sensor ⌀ 11×42,body ⌀ 40×48)
SD40NW
Overall length 100mm(sensor ⌀ 11×41,body ⌀ 40×49)
Weight
Converter
Approx. 1.2 kg  
Sensor unit
Approx. 0.5 kg
External connection
Vacuum flange (NW16, 25, or 40) or R3/8 screw
Power
24 V DC±10%, 60 V A (normal: 15 V A or less)


Vacuum deposition Model SD/LD-450