Back to Top

Hi, Guest!

  LOKASI :  Kota Bogor

Bergabung Selama : 19 Tahun

BAGIKAN :   

Bagikan :
Kontak Kami  
Field Instrumentation & Controls

TCM 230K Flow Meter

Update Terakhir
:
04 / 07 / 2025
Min. Pembelian
:
1 Unit

Harga

CALL
Bagikan
:
*Instrumentation, Control System, Automation, Cooler & Heat Exchanger, Electrical, Mechanical, Analyzers, Fabricator & Engineering Service & Training*

Detail TCM 230K Flow Meter

The TRICOR CLASSIC Series TCM 230K Coriolis Mass Flow Meter has a maximum mass flow rate of 230,000 kg/hr (8450 lb/min) or 34,720 bbl/day and nominal size of DN80 (3”), and is rated for process pressures up to 100 bar (1450 psi). Standard accuracy for the TCM 230K is 0.3%, but with a custom calibration, 0.1% accuracy is possible. These meters have good overall accuracy, zero stability, and pressure drop. The simple self-draining U-shape tube design provides for easy cleaning/flushing.

Functions & Specifications
Flow RateMass Flow Rate (max.): 230,000 kg/h [8,450 lb/min]
Volumetric Flow Rate (max.): 230,000 l/h [1,013 gpm, 34,720 oil bbl/d (US)]
Nominal Meter Size: DN80 [3”]
Pressure Rating100 bar [1,450 psi]
Accuracy (Liquids)Basic Accuracy (Mass Flow): ±0.3 % (option: up to ±0.15 %) of flow rate
Repeatability (Mass Flow): ±0.05 % of flow rate
Basic Accuracy (Volume Flow): ±0.3 % (option: up to ±0.2 %) of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.015 % of full scale
Accuracy (Gases)Basic Accuracy (Mass Flow): ±1 % (option: up to ±0.5 %) of flow rate
Repeatability (Mass Flow): ±0.25 % of flow rate
DensityDensity Range: up to 2,500 kg/m3 [2.5 g/cm3]
Density Accuracy: ±1.0 kg/m3 [±0.001 g/cm3]
Density Repeatability: ±0.5 kg/m3 [±0.0005 g/cm3]
TemperatureProcess Temperature Range: -40 °C ... +100 °C [-40 °F ... +212 °F]
Option:
-60 °C ... +200 °C [-76 °F ... +392 °F ]
Temperature Accuracy: ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability: ±0.2 °C [±0.36 °F]
Materials (Wetted Parts)Tubes: 1.4404 [AISI 316L]
Case: 1.4404 [AISI 316L]
Flow Splitter: CF3M [1.4409]
Option: NACE MR 0175/0103 compliant
Tampilkan Lebih Banyak