  • AMS 3186 Gas analyzer

AMS 3186 Gas analyzer

Update Terakhir
:
15 / 10 / 2025
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
46 kali

Harga

CALL
Bagikan
:
*Instrumentation, Control System, Automation, Cooler & Heat Exchanger, Electrical, Mechanical, Analyzers, Fabricator & Engineering Service & Training*

Detail AMS 3186 Gas Analyzer

The trace oxygen analyser AMS 3186 operates on base of an electrochemical sensor. The trace oxygen analyser AMS 3186 is a micro-processor controlled analyser for the highly accurate measurement of lowest oxygen traces.

Changes in concentrations of < 0,1 ppm of oxygen with a resolution of 0,01 ppm can be measured. The available housings are designed for use in general applications. The lowest oxygen measuring range is 0 … 1 ppm.

Available options:
bypass and purge valve, manual
2 free adjustable messages
electronically flow control
electrical/pneumatic gas pump
manual 5 way valve
particle filter 2 µm
auto-calibration, also with remote control
automatic purge of the sensor
pressure reducer
thermostatted measuring cell
different housings

Technical data
Analyser
AMS 3186
Measuring principle
Electrochemical oxygen sensor
Application
Gases Industries, Chemical Industries, Process Measurement
Measuring range
4, automatic selection, digital ID, adjustable
0 … 10, 0 ... 100, 0 ... 1.000, 0 … 10.000 ppmv
Analogue signal port
0 (4) … 20mA, galvanically separated,
with measuring range changeover and digital identification
Reproducability
+/– 2 % of the measuring value
Resolution
0,01 ppm – C(O2) – 1 ppm, depending on the O2 concentration
T90-Time
ca. 40 seconds
Long term drift
< 1% per month
Display
2* 16 digit, illuminated LCD display
Analyser Status Messages
System Status, Calibration, Service via potential free contact relays
Oxygen Messages
2 Messages, configurable as Oxygen Alarm HIGH / LOW via potential free contact relays
Gas connection
inlet / outlet 3 / 6 mm ferrule pack
Gas sampling
built-in inlet / outlet valve, flowmeter
Sample flow
min. 20 Nl/h, max. 40 Nl/h
Sample pressure (inlet)
min. 1,01 bar abs., max. 2 bar abs.
Sample pressure (measuring cell)
max. 50 mbar pressure
Digital communication
serial interface RS 232
Ambient operating temp.
– 5 °C up to + 45 °C
Relative humidity of the gas
0 … 99 % not condensing
Power supply
230 VAC, 24 VDC
Protection / Housing / Dimensions
IP 54 / wall mounting housing
IP 20 / 19“ rack, 3 HU / IP 20 / 63 TU portable housing
Ex-classification
in IP 55 wall mounting housing with inert gas purge also
qualified for applications in Ex-Zone 2
Weight
5 – 7 kg
Options
bypass- and purge valve, manual
measuring range max. bypass- and purge valve, manual
measuring range max. 4, automatic selection, digital ID
electronically flow control<cr>electrical/pneumatic gas pump
manual 5 way valve
particle filter 2-7µm
auto-calibration, also with remote control
automatic purge of the sensor
pressure reducer max. 10 bar, out 50 mbar
thermostatted measuring cell