Back to Top

Hi, Guest!

  LOKASI :  Kota Bogor

Bergabung Selama : 17 Tahun

BAGIKAN :   

Bagikan :
Kontak Kami  
Instrumentation & Valves

LU-CLT flange liquid transmitter.

Update Terakhir
:
25 / 01 / 2024
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
7 kali

Harga

CALL
Bagikan
:
*Instrumentation, Control System, Automation, Cooler & Heat Exchanger, Electrical, Mechanical, Analyzers, Fabricator & Engineering Service & Training*

Detail LU-CLT Flange Liquid Transmitter.

LU-CLT flange liquid transmitter.

1.characteristic:

LU-CLT may accurate measure liquid & density which in each kind of container. There are flat-flange & in-line-flange, and size is 3 inch (3’’) or 4 inch (4’’), specification is 1501b or 3001b, may special make for user’s requirement. If no indication, our company will deliver the flange of 3’’ & 1501b. Flange diaphragm material may be selected.



1. technical performance

·to subject: liquid in breached or seal container

·range ability:

single-flat flange type:

LU-CLT-3310
0-1.2-7.2Kpa
LU-CLT-4410
0-3-36Kpa
LU-CLT-4510
0-30-180Kpa
LU-CLT-4610
0-160-1000Kpa
LU-CLT-4710
0-400-2500Kpa
Single-in-line flange type:

LU-CLT-3330
0-1.2-7.2Kpa
LU-CLT-4430
0-6-36Kpa
LU-CLT-4530
0-30-180Kpa
LU-CLT-4630
0-160-1000Kpa
LU-CLT-4730
0-400-2500Kpa


·output: 4-20mA DC

·power: 24VDC, it may be 12VDC if non-load, max. is 45VDC

·Indicate meter (field): scale gauge length: 30mm,

grade: 2.5

·Isolating explosion: ds Ⅱ BT5, Instrinsically-safety: ia Ⅱ CT5

·positive & negative transfer: up and low may not exceed the range limit after positive & negative transfer, whatever the output is.

Max. positive transfer: 500% of the min. span.

Max. negative transfer: 600% of the min. span.

·Span & Zero: external continually adjusted

·Temperature:

temperature of operating for amplifier: -25℃ ~ +90℃

temperature of operating for sensor: -40℃ ~ +104℃

·Relative humidity: 0~100%

·Sensor capacity changes: <0.16cm3

·Static-pressure and Over-pressure limit:

1501b flange: 42Kpa (AP)~1.9Mpa (37℃)

3001b flange: 42Kpa (AP)~4.9Mpa (37℃)

·Damp: continually adjusted when time constant is between 0.2~1.67 seconds.

·Settling time: 2s,



2. performance index (note: test under the condition of none shift, max. range status of sensor, 316L stainless isolating diaphragm and other standard condition)

·Accuracy: ±0.25% of the span, including the synthesize errors of linear, change-difference and repeat.

·Stability: ±0.25% of max. range (12 months)

·Temperature affect:

zero error:±0.75% / 55℃, total errors:±1.5% / 55℃, when max. range;

zero error:±4.5% / 55℃, total errors:±5.25% / 55℃, when min. range;



· static-pressure affect: zero error <±0.5% of max. range, when add 4Mpa (AP);

range error is system error, can be calibrated.

·vibration affect: ±0.05% / g of the max. range, when 200Hz, any axis up.

·Power affect: <0.005%/V of output range

·Load affect: none affect when voltage >12VDC input to the transmitter.



3. structure index:

·Structure material: diaphragm: 316 stainless steel, hastelloy C, Monel alloy, Tantalum;

O ring: Fluorin rubber;

Flange & bolt: 316 stainless steel;

Fill oil: silicon oil or inert liquid;

Electric shell: low-Cu & aluminum alloy

Plating of electric shell: toast lacquer of amido, formyl, ethene & colophony;

·pressure-lead connector:

on high-pressure side: 3’’ or 4’’, 1501b or 3001b flange;

on low-pressure side: flange NPT 1/4 (taper pipe screw thread);

connection head screw thread NPT 1/2 (selected);

·electric parts connector:

down-lead conduit NPT 1/2 line-through hole;

·net weight: 2.4kg (exclude the selected parts)
Level Transmitter
Tampilkan Lebih Banyak