Oxygen Gas Analyzer. Model LC 860

Update Terakhir
:
18 / 04 / 2024
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
126 kali

Harga

CALL
Bagikan
:
*Instrumentation, Control System, Automation, Cooler & Heat Exchanger, Electrical, Mechanical, Analyzers, Fabricator & Engineering Service & Training*

Detail Oxygen Gas Analyzer. Model LC 860

Oxygen Analyzer for Semiconductors, Electronic Components
LC-860_Specifications
*Low concentration measurement
*Measurement range from ppb level to 100%
*Easy to operate
*Easy operation by separate keys.
*Purge function
*The more precious measurement is possible by stablizing the reference gas. (for models with purge function only)
*High reliability sensor
*Processing to prevent from degradation for the sensor is available (option).

Measurement principle Battery-powered zirconia oxygen analyzer
Type Desktop type / Panel mount type
Display system 6-digit digital display (concentration display)
Measurement range 0-1 / 10 / 100 / 1000ppm / 1 / 10 / 100vol%O2; 10-20 to 10-0atm
Automatic range
Repeatability Within ±1% of full scale
xygen concentrations less than 1ppm and in the range 0-1ppm, atm are not under the warranty range
Sampling system Continuous suction with internal pump
Sample gas requirements Pressure: Pressurization at 30KPa or less
Flow rate: Up to 1,500mL/min
Humidity: Dew point below ambient temperature
Temperature: 0-50ºC
Others: Not to contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable ingredients (including gas), oil or moisture
Reference gas Atmospheric air
Recorder output Oxygen level output: 4-20mA/0-10V
4-20mA: Insulated; load resistance of 600Ω or less
0-10V: Insulated; load resistance of 500Ω or more
Recorder output range taken as full scale and oxygen concentration given in linear output
Output range: 0-100% / 0-10% / 0-1% / 0-1000ppm / 0-100ppm / 0-10ppm / 0-1ppm / 10-20-10-0 or 4 optional automatic/fixed ranges
Transmission output RS-232C
Alarm output FAIL (device error): 1 point
Non-voltage contact; contact capacity: 24VDC/AC or less, 0.1A or less
Contact point closes with device error (contact point operation adjustable)
ALM (concentration alarm): 2 points
Non-voltage contact; contact capacity: 24VDC/AC or less, 0.1A or less
Contact point closes with alarm (contact point operation adjustable)
RDY (warmup signal): 1 point
Non-voltage contact; contact capacity: 24VDC/AC or less, 0.5A or less
Contact point closes during warmup (contact point operation adjustable)
* Minimum open/close capacity of the non-voltage contact point is 12V or higher; unable to respond to tiny load
MRK (range marker) output: 3 points
Non-voltage contact; contact capacity: 24VDC/AC or less, 0.1A or less
Warmup time Under 20 min.
Dimensions Body: 288(W)×144(H)×400(D)mm (excludes protruding parts)
Weight Approx. 10 kg
Gas connection INLET: Rc1/8
BYPASS OUT: Rc1/8
OUTLET: Rc1/4
Power 100-120VAC±10% 200VA 50Hz/60Hz

Model LC 860 Oxygen Gas Analyzer